Shopping Cart

Cart is Empty

PS 38-2-2025

Active
Plastics piping systems for hot and cold water installations — Crosslinked polyethylene (PE-X) — Part 2: Pipes
Committee: Plastic Pipes and Fittings
Sector: Mechanical and Metals
Available Standards
Original Standard
إنجليزي (English) 43 Page 2025
International Classification for Standards (ICS)
Code Classification
23.040.20 Plastics pipes
Adopted Standards
Standards / Amendment / Corrigendum
1 ISO 15875-2:2003
2 Amd 1:2007
3 Amd 2:2020
Replacement Sequence
Scope

This Part of EN ISO 15875 specifies the characteristics of pipes made from crosslinked polyethylene (PE-X) for
piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water,
whether or not intended for human consumption (domestic systems), and for heating systems, under design
pressures and temperatures appropriate to the class of application (see Table 1 of EN ISO 15875-1:2003).
This standard covers a range of service conditions, (application classes), design pressures and pipe dimension
classes. For values of TD, Tmax and Tmal in excess of those in Table 1 of Part 1, this standard does not apply.
NOTE 1 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their
particular requirements and any relevant national regulations and installation practices or codes.
It also specifies the test parameters for the test methods referred to in this standard.
In conjunction with the other Parts of EN ISO 15875 (see Foreword) it is applicable to PE-X pipes, their joints and
to joints with components of PE-X, other plastics and non-plastics materials intended to be used for hot and cold
water installations.
It is applicable to pipes with or without (a) barrier layer(s).
NOTE 2 In the case of plastics pipes provided with a thin barrier layer, e.g. to prevent or greatly diminish the diffusion of gases and the
transmission of light into or through the pipe wall, the design stress requirements are totally met by the base polymer (PE-X).