Shopping Cart

Cart is Empty

PS 1547-2-2026

Active
Water quality — Determination of total cyanide and free cyanide using flow analysis (FIA and CFA) — Part 2: Method using continuous flow analysis (CFA)
Committee: Environment
Sector: Environment
Available Standards
Original Standard
إنجليزي (English) 29 Page 2026
International Classification for Standards (ICS)
Code Classification
13.060.50 Examination of water for chemical substances
Adopted Standards
Standards / Amendment / Corrigendum
1 ISO 14403-2:2012
Replacement Sequence
Scope

This part of PS 1547 specifies methods for the determination of cyanide in various types of water (such as ground, drinking, surface, leachate, and waste water) with cyanide concentrations usually from 2 μg/l to 500 μg/l expressed as cyanide ions in the undiluted sample. The range of application can be changed by varying the operation conditions, e.g. by diluting the original sample or changing the pathlength of the flow cell.


In this method, a suitable mass concentration range from 10 μg/l to 100 μg/l is described.


Seawater can be analysed with possible changes in sensitivity and adaptation of the reagent and calibration solutions to the salinity of the samples.